6 Device PowerSupply General Purpose Power Supply (GPDPS)
166 System Reference, January 2001
Table 30 Wait time required for measurement path to settle
3. In order to select the subsequent measurement path
(autoranging), a single measurement is used.
4. After the measurement path has settled, the remaining
measurements are performed.
Table 31 Number of samples depending on range
Measurement time per sample:
30 µs min. (ADC + data transfer) +
10...50 µs depending on computer type and load
NOTE The time required for a single measurement varies,
because a multitasking system is employed which is inter-
ruptible. Thus, the values given are statistical.
NOTE If the disconnect pin list in the IDDQ test function is not
empty, it will require additional time to open the I/O pin
relays.
Range Wait time (GP-DPS)
Voltage 0.5ms
10 A 0.07 ms
300mA 0.1 ms
10 mA 0.1 ms
100 µA5ms
Measurement
Range
Samples
Voltage 1
10 A 16
300 mA 16
10 mA 32
100 µA 64 (+ user samples)